10000 psi, 3/8" ports, 5 gpm max flow rate.Application: Double acting cylinders.
Actuation: Solenoid operated.
Functions: “Advance”, “hold” and “return”. The “Posi-Check” feature holds the load when shifting from the “advance” to the “hold” position.
Used on these pumps: PE17, PE21, PE30 (with carrying handles removed), PE46, PE55, PE84, PE90, PE120, PE200, PE400, PQ60 and PQ120 series.
A gauge may be attached if desired.
To prevent sudden, uncontrolled descent of a load as it is being lowered, use
more a No. 9596 Load Lowering Valve or No. 9720 Counter Balance Valve in conjunction with the directional valve used in your application. less