Call Us Today: (800) 633-8234

Catalog

  • Item Image - Relief Valve
  • Item Image - Load Lowering Valve
  • Product Image - Air Actuated Valve

    10000 psi, 3/8" ports, 5 gpm max flow rate.
    Application: Single or double acting cylinders. When used with single acting cylinders, one port should be plugged.
    Actuation: Air operated. Functions: Oil is directed to “extend” side of cylinder, oil from “retract” side goes to reservoir; cylinder “holds” with pump shut off. Oil is directed to “retract” side of cylinder; oil from “extend” side goes to reservoir.
    Used on these pumps: PA17, PA46 and PA55 series.
    Cylinder will not “hold” in the “return” position with motor running or shut off. Valve are is shipped without controls. The valve can be used with the 209593 remote hand control.
    To prevent sudden, uncontrolled descent of a load as it is being lowered, use a No. 9596 Load Lowering Valve or No. 9720 Counter Balance Valve in conjunction with the directional valve used in your application.
    Conversion kit 251528 must be used when mounting the valves on PA17 or PE17 pumps.

^