NOTE: Pressure relief valve setting is 12000 psi. Operating pressure is 10000 psi and max. flow rate is 5 gpm.
Caution: To prevent sudden, uncontrolled descent of a load as it is being lowered, use a No. 9596 Load Lowering Valve or No. 9720 Counter Balance Valve in conjunction with the directional valve used in your application.