Product Image - 3/4-Way/2-Position Manual Valves

3 / 4-Way/2-Position Manual Valves


  • Lightweight, ergonomic design for ease of use
  • Adjustable jaw widths from 2.75" to 8.50" for a wide range of applications
  • Single-acting, spring return RC Series cylinders for fast trouble-free operation
Dimensional Drawing

4-way/3-Position (Tandem Center) Valve With Posi-Check


Application: Double-acting cylinders.
Actuation: Lever operated, detent positioned.
Functions: “Advance”, “hold” and “return”. The “Posi-Check” feature guards against pressure loss when shifting from “advance” to “hold” position.
Used on these pumps: P460, PA6D, PA17, PA46, PA55, PE17, PE21, PE30, PE46, PE55, PE84, PE90, PE120,PE200, PE400, PED, PG30, PG55, PG120, PG400, PQ60 and PQ120 series
Product Image - 4 Way / 3 Position (Tandom Centre) and (Open Centre) Manual Valves

4-way/3-Position (Tandem Center) and (Open Center) Manual Valves

(2)
Application: Single- or double-acting cylinders.
Actuation: Lever operated, detent positioned.
Functions: The 9500 provides “advance”, “hold” and “return”. The 9511 (open center) valve can be used if holding is not a requirement, as when running two separate hydraulic tools.Provides “advance” and “return” only.
Used on these pumps: P460, PA17, PA46, PA55, PE17, PE21, PE30, PE46, PE55, PE84, PE90, PE120, PE200, PE400, PG30, PG55, PG120, PG400, PQ60 and PQ120 series.
Product Image - 4 Way/3 Position (Closed Center) Manual Valve with Posy Check

4-way/3-Position (Closed Center) Manual Valves With "POSI-CHECK"


Application: Single- or double-acting cylinders.
Actuation: Lever operated, detent positioned.
Functions: Similar to 9506, but is a closed center valve with “Position-Check”. Generally used to operate multiplecylinders with a single pump. Provides “advance”, “hold” and “return”. The “Posi-Check” featureguards against pressure loss when shifting from the “advance” to “hold” position. See note on page 146 regarding plugging of ports and resulting heat build-up.
Used on these pumps: P460, PA17, PA46, PA55, PA60, PE17, PE21, PE30, PE46, PE55, PE84, PE90, PE120, PE200, PE400, PQ60 and PQ120 series.
Product Image - 4 Way / 3 Position (Closed Center) Manual Valve

4-way/3-Position (Closed Center) Manual Valves


Application: Single- or double-acting cylinders.
Actuation: Lever operated, detent positioned.
Functions: “Advance”, “hold” and “return”. Closed center design makes valve suitable for operating multiple cylinders from a single pump. See note on page 146 regarding plugging of ports and resulting heat build-up.
Used on these pumps: P460, PA17, PA46, PA55, PA60, PE17, PE21, PE30, PE46, PE55, PE84, PE90, PE120, PE200, PE400, PQ60 and P120 series.
Product Image - 4-way/3-position (tandem center) pilot operated solenoid valve

4 - Way / 3 - Position (Open Center) Solenoid Valve

(3)
10000 psi, 3/8" ports, 5 gpm max flow rate.
Application: Double acting cylinders.
Actuation: Solenoid operated,115 volt,50/60 Hz
Functions: “Advance", open center and “return” positions. Cylinder port and pump port are open to reservoir in "neutral".
Used on these pumps: Furnished with pilot lines and adapters for PESO (with carrying handles removed), PE55, PE90 and PE120 series. For other pump models, consult factory.
A pressure switch and/or gauge may be attached if desired.
To prevent sudden, uncontrolled descent of a load as it is being lowered, use a No. 9596 Load Lowering Valve or No. 9720 Counter Balance Valve in conjunction with the directional valve used in your application.
Product Image - 4-way/3-position (open center) solenoid valve

4 - Way / 3 - Position (Tandem Center) Pilot Operated Solenoid Valve

(4)
10000 psi, 3/8" ports, 5 gpm max flow rate.
Application: Double acting cylinders.
Actuation: Solenoid operated.
Functions: “Advance”, “hold” and “return”. The “Posi-Check” feature holds the load when shifting from the “advance” to the “hold” position.
Used on these pumps: PE17, PE21, PE30 (with carrying handles removed), PE46, PE55, PE84, PE90, PE120, PE200, PE400, PQ60 and PQ120 series.
A gauge may be attached if desired.
To prevent sudden, uncontrolled descent of a load as it is being lowered, use a No. 9596 Load Lowering Valve or No. 9720 Counter Balance Valve in conjunction with the directional valve used in your application.
Product Image - 4-way/3-position (tandem center) manual valve

4 - Way / 3 - Position (Tandem Center) Manual Valve


10000 psi, 3/8" ports, 5 gpm max flow rate.
Application: Single strand, single acting stressing jacks with Power Wedge seater.
Actuation: Lever operated, detent positioned.
Used on these pumps: PA17 (These pumps may have reduced first flow stage characteristics due to internal valve restrictions.), PA46 (These pumps may have reduced first flow stage characteristics due to internal valve restrictions.), PA55, PE17 (These pumps may have reduced first flow stage characteristics due to internal valve restrictions.), PE21 (These pumps may have reduced first flow stage characteristics due to internal valve restrictions.), PE30, PE46 (These pumps may have reduced first flow stage characteristics due to internal valve ...
Product Image - “Twin” 4-way/3-position (tandem center) manual valve

Twin 4 - Way / 3- Position (Tandem Center) Manual Valve


10000 psi, 3/8" ports, 5 gpm max flow rate.
Application: Multistrand, double acting stressing jacks with an auxiliary seating cylinder.
Actuation: Dual lever operated, detent positioned.
Used on these pumps: PA17 (These pumps may have reduced first flow stage characteristics due to internal valve restrictions.), PA46 (These pumps may have reduced first flow stage characteristics due to internal valve restrictions.), PA55, PE17(These pumps may have reduced first flow stage characteristics due to internal valve restrictions.), PE21 (These pumps may have reduced first flow stage characteristics due to internal valve restrictions.), PE30, PE46 (These pumps may have reduced first flow stage characteristics due to internal valve ...